Example Architectural Decision – Jumbo Frames with IP Storage (Use Jumbo Frames)

Problem Statement

When using IP based storage over a converged 10GB network, should Jumbo Frames be used?

Requirements

1. Fully Supported storage

2. Maximum vSphere environment availability

3. Maximize performance where possible

Assumptions

1. Dedicated 10GB Storage Network which is highly available

2. Two 10GB connections per ESXi host dedicated to IP Storage

3. Storage array supports Jumbo Frames

4. Benefit of Jumbo Frames outweighs the complexity to implement/maintain/support

5. Network performance is constrained at an interrupt level

Constraints

1. Maximum of two connections per ESXi host for IP Storage

Motivation

1. Maximum performance and security

Architectural Decision

Use Jumbo Frames

Justification

1. There is a dedicated physical network for IP storage

2. All devices end to end support Jumbo Frames and this is enabled on all switches globally

3. As only IP storage traffic traverses the dedicated network, a larger MTU will not have any adverse effects on data network traffic.

4.  IP storage packets will not be fragmented or dropped as the storage network has been verified and configured to support Jumbo Frames. Thus avoiding costly re-transmits

5. No routing exists (or is required) for the IP storage network, as such the environment is flat and simple to support

6. IP Storage performance will not be constrained by MTU

7. A standard MTU of 1500 can optionally be configured at the VMKernel layer if performance is negatively impacted by Jumbo Frames without the need to modify the switch configuration which will support up to 9216 MTU

8. Increasing the MTU will decrease the number of packets required for the same bandwidth to help prevent IP storage network being constrained at an interrupt level

Implications

1. A dedicated network needs to be maintained for IP storage which reduces consolidation

2. Storage network needs to be configured for Jumbo Frames

3. The Storage controller needs to be configured for Jumbo Frames

4. The VMKernel/s need to be configured for Jumbo Frames

5. Where the networks becomes constrained at either an interrupt or throughput level, any benefit of Jumbo Frames may be reduced or lost and IP storage performance may degrade

Alternatives

1. Do not use Jumbo Frames

2. Use Jumbo Frames in a converged network (ie: No dedicated IP Storage switches)

Relates Articles

1. Example Architectural Decision – Jumbo Frames for IP Storage (Use Jumbo Frames)

 Contributors

Thanks to Rob McNab (IBM) and Peter McCrystal (IBM) for their input into this example architectural decision.

Example VMware vNetworking Design w/ 2 x 10GB NICs (IP based or FC/FCoE Storage)

I have had a large response to my earlier example vNetworking design with 4 x 10GB NICs, and I have been asked, “What if I only have 2 x 10GB NICs”, so the below is an example of an environment which was limited to just two (2) x 10GB NICs and used IP Storage.

If your environment uses FC/FCoE storage, the below still applies and the IP storage components can simply be ignored.

Requirements

1. Provide high performance and redundant access to the IP Storage (if required)
2. Ensure ESXi hosts could be evacuated in a timely manner for maintenance
3. Prevent significant impact to storage performance by vMotion / Fault Tolerance and Virtual machines traffic
4. Ensure high availability for all network traffic

Constraints

1. Two (2) x 10GB NICs

Solution

Use one dvSwitch to support all VMKernel and virtual machine network traffic and use “Route based of Physical NIC Load” (commonly refereed to as “Load Based teaming”).

Use Network I/O control to ensure in the event of contention that all traffic get appropriate network resources.

Configure the following Network Share Values

IP Storage traffic : 100
ESXi Management: 25
vMotion: 25
Fault Tolerance : 25
Virtual Machine traffic : 50

Configure two (2) VMKernel’s for IP Storage and set each on a different VLAN and Subnet.

Configure VMKernels for vMotion (or Multi-NIC vMotion), ESXi Management and Fault Tolerance and set to active on both 10GB interfaces (default configuration).

All dvPortGroups for Virtual machine traffic (in this example VLANs 6 through 8) will be active on both interfaces.

The above utilizes LBT to load balance network traffic which will dynamically move workload between the two 10GB NICs once one or both network adapters reach >=75% utilization.

vNetworking BLOG 2x10gb

Conclusion

Even when your ESXi hosts only have two x 10Gb interfaces, VMware provides enterprise grade features to ensure all traffic (including IP Storage) can get access to sufficient bandwidth to continue serving production workloads until the contention subsides.

This design ensures that in the event a host needs to be evacuated, even during production hours, that it will complete in the fastest possible time with minimal or no impact to production. The faster your vMotion activity completes, the sooner DRS can get your cluster running as smoothly as possible, and in the event you are patching, the sooner your maintenance can be completed and the hosts being patched are returned to the cluster to serve your VMs.

Related Posts

1. Example Architectural Decision – Network I/O Control for ESXi Host using IP Storage (4 x 10 GB NICs)
2. Network I/O Control Shares/Limits for ESXi Host using IP Storage

Example Architectural Decision – Network I/O Control Shares/Limits for ESXi Host using IP Storage

Problem Statement

With 10GB connections becoming the norm, ESXi hosts will generally have less physical connections than in the past where 1Gb was generally used, but more bandwidth per connection (and in total) than a host with 1GB NICs.

In this case, the hosts have only to 2 x 10GB NICs and the design needs to cater for all traffic (including IP storage) for the ESXi hosts.

The design needs to ensure all types of traffic have sufficient burst and sustained bandwidth for all traffic types without significantly negatively impacting other types of traffic.

How can this be achieved?

Assumptions

1. No additional Network cards (1gb or 10gb) can be supported
2. vSphere 5.1
3. Multi-NIC vMotion is desired

Constraints

1. Two (2) x 10GB NICs

Motivation

1. Ensure IP Storage (NFS) performance is optimal
2.Ensure vMotion activities (including a host entering maintenance mode) can be performed in a timely manner without impact to IP Storage or Fault Tolerance
3. Fault tolerance is a latency-sensitive traffic flow, so it is recommended to always set the corresponding resource-pool shares to a reasonably high relative value in the case of custom shares.
4. Proactively address potential contention due to limited physical network interfaces

Architectural Decision

Use one dvSwitch to support all VMKernel and virtual machine network traffic.

Enable Network I/O control, and configure NFS and/or iSCSI traffic with a share value of 100 and ESXi Management , vMotion & FT which will have share value of 25. Virtual Machine traffic will have a share value of 50.

Configure the two (2) VMKernel’s for IP Storage on dvSwitch and set to be Active on one 10GB interface and Standby on the second.

Configure two VMKernel interfaces for vMotion on the dvSwitch and set the first as Active on one interface and standby on the second.

A single VMKernel will be configured for Fault tolerance and will be configured as Active on one interface and standby on the second.

For ESXi Management, the VMKernel will be configured as Active on the interface where FT is standby and standby on the second interface.

All dvPortGroups for Virtual machine traffic will be active on both interfaces.

Justification

1. The share values were chosen to ensure IP storage traffic is not impacted as this can cause flow on effects for the environments performance. vMotion & FT are considered important, but during periods of contention, should not monopolize or impact IP storage traffic.
2. IP Storage is more critical to ongoing cluster and VM performance than ESXi Management, vMotion or FT
3. IP storage requires higher priority than vMotion which is more of a burst activity and is not as critical to VM performance
4. With a share value of 25,  Fault Tolerance still has ample bandwidth to support the maximum supported FT machines per host of 4 even during periods of contention
5. With a share value of 25, vMotion still has ample bandwidth to support multiple concurrent vMotion’s during contention however performance should not be impacted on a day to day basis. With up to 8 vMotion’s supported as it is configured on a 10GB interface. (Limit of 4 on a 1GB interface) Where no contention exists, vMotion traffic can burst and use a large percentage of both 10GB interfaces to complete vMotion activity as fast as possible
6. With a share value of 25,  ESXi Management still has ample bandwidth to continue normal operations even during periods of contention
7. When using bandwidth allocation, use “shares” instead of “limits,” as the former has greater flexibility for unused capacity redistribution.
8. With a share value of 50,  Virtual machine traffic still has ample bandwidth and should result in minimal or no impact to VM performance across 10Gb NICs
9. Setting Limits may prevent operations from completing in a timely manner where there is no contention

Implications

1. In the unlikely event of significant and ongoing contention, performance for vMotion may affect the ability to perform the evacuation of a host in a timely manner. This may extend scheduled maintenance windows.
2. VMs protected by FT may be impacted

Alternatives

1. Use a share value  of 50 for IP storage traffic to more evenly share bandwidth during periods of contention. However this may impact VM performance eg: Increased CPU WAIT if the IP storage is not keeping up with the storage demand