What’s .NEXT 2016 – Metro Availability Witness

In 2014, Nutanix introduced Metro Availability which allows Virtual Machines to have mobility between sites as well as to provide failover in the event of a site failure.

The goal of the Metro Availability (MA) Witness is to automate failovers in case of inter-site network failures or site failures. By the virtue of running the Witness in a different location than the two Metro Sites, it provides the ‘outside’ view that can determine whether a site is actually down or whether the network connection between the two sites is down, avoiding a split-brain scenario that can occur without an external Witness.

The main functions of a Witness include:

  • Making failover decision in the event of site or inter-site network failure
  • Avoiding split brain where the same container is active on both sites
  • Design to handle situations where a single storage or network domain fails

For example, in the case of a Metro Availability (MA) relationship between clusters, a Witness residing in a separate failure domain (e.g.: 3rd site) decides which site should be activated when a split brain occurs due to a WAN failure, or in the situation where a site goes down. For that reason, it is a requirement that there are independent network connections for inter-site connectivity *and* for connections to the witness.

How Metro works without a Witness:

In the event of the primary site failure (the site where the Metro container is currently active) or the links between the sites going offline, the Nutanix administrator is required to manually Disable Metro Availability and Promote the Container to Active on the site where VMs are desired to be ran. This is a quick and simple process, but it is not automated which may impact the Recovery Time Objective (RTO).

In case of a communication failure with the secondary site (either due to the site going down or the network link between the sites going down), the Nutanix administrator can configure the system in two ways:

  • Automatic: the system will automatically disable Metro Availability on the container on the primary site after a short pause if the secondary site connection doesn’t recover within that time
  • Manual: wait for the administrator to manually take action

MetroNoWitness

How Metro Availability (MA) works with the witness:

With the new Witness capability, the process of disabling Metro Availability and Promoting the Container in case of a site outage or a network failure is fully automated which ensures the fastest possible RTO.  The Witness functionality is only used in case of a failure, meaning a Witness failure itself will not affect VMs running on either site.

MetroWithWitness

Failure Scenarios Addressed by MA Witness.

There are a number of scenarios which can occur and Metro Availability responds differently depending on if MA is configured in “Witness mode”, “Automatic Resume mode” or in “Manual mode”.

The following table details the scenarios and the behaviour based on the configuration of Metro Availability.

MetroFailureScenarios3

In all cases except a failure at both Site 1 and Site 2, the MA Witness automatically handles the situation and ensures the fastest possible RTO.

The following videos show how each of the above scenarios function.

Deployment of the Metro Availability (MA) Witness:

The Witness capability is deployed as a stand-alone Virtual Machine, that can be imported on any hypervisor in a separate failure domain, typically a 3rd site.  This VM can run on non-Nutanix hardware.  This site is expected to have dedicated network connections to Site 1 and Site 2 to avoid a single point of failure.

As a result, MA Witness is quick and easy to deploy, resulting in lower complexity and risk compared to other solutions on the market.

Summary:

The Nutanix Metro Witness completes the Nutanix Metro Availability functionality by providing completely automatic failover in case of site or networking failures.

Related .NEXT 2016 Posts

Example Architectural Decision – Host Isolation Response for a Nutanix Environment

Problem Statement

What are the most suitable HA / host isolation response when using Nutanix?

Assumptions

1. vSphere 5.0 or greater
2. Two x 10GB Network interfaces are shared for Nutanix Storage Traffic and Virtual Machine Traffic

Motivation

1. Minimize the chance of a false positive isolation response
2. Ensure in the event the storage is unavailable that virtual machines are promptly shutdown to enable HA to recover the VMs in a timely manner (where other hosts are unaffected by isolation) and to prevent a “split brain” scenario
3. Ensure maximum availability

Architectural Decision

Turn off the default isolation address and configure the below specified isolation addresses, which check connectivity to multiple Nutanix Controller VMs (CVMs) on the IP Storage VLAN.

Configure the following Isolation addresses

das.isolationaddress1 : NDFS Cluster IP Address

Configure Host Isolation Response to: Power Off

For Nutanix Controller VMs override the cluster setting and configure Host Isolation Response to “Leave Powered On”

Justification

1. The ESXi Management traffic along with the Virtual machine traffic and inter-Nutanix node storage traffic is running over 2 x 10GB connections. Using the ESXi management gateway (default isolation address) to check for isolation is not suitable as the management network can be offline without impacting the IP storage or data networks. This situation could lead to false positives isolation responses.
2. The isolation addresses chosen tests IP storage connectivity over the converged 10Gb network and in the event this is unavailable, there is no point testing further connectivity as Virtual machines cannot function without their storage
3. In the event the Nutanix cluster IP address cannot be reached by ICMP the Node will not be able to properly function. As such, triggering isolation response and powering off the VMs based on this criteria is logical as the VMs will not be able to function under these conditions.
4. In the event the NDFS Cluster IP address does not respond to ICMP on the Management interfaces it is likely there has been an isolation event OR a catastrophic failure in the environment, either to the network, or the storage controllers themselves, in which case the safest option is to Power Off the VMs.
5. In the event the isolation response is triggered and the isolation does not impact all hosts within the cluster, the VMs can be restarted by HA onto a surviving host and resume functioning
6. Using the Nutanix Controller VM (CVM) IP address (192.168.5.2) for the Isolation address is not suitable as this address exists on each ESXi hosts and as such it is not a good candidate for isolation detection as the host will always be able to find this address even when the network is offline due to the CVM being local to the host
7. The Nutanix Controller VM accesses local storage and can continue to run locally even in an isolation event. When the isolated event is over, the CVM will then regain connectivity to the other CVMs in the Nutanix cluster.
8. Shutting down the CVM would only increase the recovery time once the isolation even is over and has no added benefits.

Implications

1. In the event the host cannot reach any of the isolation addresses, virtual machines will be powered off.
2. Initial cluster setup would require the vSphere administrator to override the Cluster settings for each Controller VM. Note: This is a one time task (Set & Forget)

Alternatives

1. Set Host isolation response to “Leave Powered On”
2. Do not use Datastore heartbeating
3. Use the default isolation address
4. Leave the CVM on the default cluster setting and “Shutdown” on isolation

Related Articles

1. VMware Host Isolation Response in a Nutanix Environment #NoSAN

2. Storage DRS and Nutanix – To use, or not to use, that is the question?

3. VMware HA and IP Storage

Example Architectural Decision – BC/DR Solution for vCloud Director

Problem Statement

What is the most suitable BC/DR solution for a vCloud director environment?

Requirements

1. Ensure the vCloud solution can tolerate a site failure in an automated manner
2. Ensure the vCloud solution meets/exceeds the RTO of 4hrs
3. Comply with all requirements of the Business Continuity Plan (BCP)
4. Solution must be a supported vSphere / vCloud Configuration
5. Ensure all features / functionality of the vCloud solution are available following a DR event

Assumptions

1. Datacenters are in an Active/Active configuration
2. Stretched Layer 2 network across both datacenters
3. Storage based replication between sites
4. vSphere 5.0 Enterprise Plus or later
5. VMware Site Recovery Manager 5.0 or later
6, vCloud Director 1.5 or later
7. There is no requirement for workloads proposed to be hosted in vCloud to be at one datacenter or another

Constraints

1. The hardware for the solution has already been chosen and purchased. 6 x 4 Way, 32 core Hosts w/ 512GB RAM and 4 x 10GB
2. The storage solution is already in place and does not support a Metro Storage Cluster (vMSC) configuration

Motivation

1. Meet/Exceed availability requirements
2. Minimize complexity

Architectural Decision

Use the vCloud DR solution as described in the “vCloud Director Infrastructure Resiliency Case Study” (By Duncan Epping @duncanyb and Chris Colotti @Ccolotti )

In Summary, Host the vSphere/vCloud Management virtual machines on an SRM protected cluster.

Use a dedicated cluster for vCloud compute resources.

Configure the vSphere cluster which is dedicated to providing compute resources to the vCloud environment (Provider virtual data center – PvDC) to have four (4) compute nodes  located at Datacenter A for production use and two (2) compute nodes located at Datacenter B (in ”Maintenance mode”) dedicated to DR.

Storage will not be stretched across sites; LUNs will be presented locally from “Datacenter A” shared storage to the “Datacenter A” based hosts. The “Datacenter A” storage will be replicated synchronously to “Datacenter B” and presented from “Datacenter B” shared storage to the two (2) “Datacenter B” based hosts. (No stretched Storage between sites)

In the event of a failure, SRM will recover the vSphere/vCloud Management virtual machines bringing back online the Cloud, then a script as the last part of the SRM recovery plan, Mounts the replicated storage to the ESXi hosts in “Datacenter B” and takes the two (2) hosts at “Datacenter B” out of maintenance mode. HA will then detect the virtual machines and power on them on.

Justification

1. Stretched Clusters are more suited to Disaster Avoidance than Disaster Recovery
2. Avoids complex and manual  intervention in the case of a disaster in the case of a stretched cluster solution
3. A Stretched cluster provides minimal control in the event of a Disaster where as in this case, HA simply restarts VMs once the storage is presented (automatically) and the hosts are taken out of Maintenance mode (also automated)
4. Having  two (2) ESXi hosts for the vCloud resource cluster setup in “Datacenter B” in “Maintenance Mode” and the storage mirrored as discussed  allows the virtual workloads to be recovered in an automated fashion as part of the VMware Site Recovery Manager solution.
5. Removes the management overhead of managing a strecthed cluster using features such as DRS affinity rules to keep VMs on the hosts on the same site as the storage
6. vSphere 5.1 backed resource clusters support >8 host clusters for “Fast provisioning”
7. Remove the dependency on the Metropolitan Area Data and Storage networks during BAU and the potential impact of the latency between sites on production workloads
8. Eliminates the chance of a “Split Brain” or a “Datacenter Partition” scenario where VM/s can be running at both sites without connectivity to each other
9. There is no specific requirement for non-disruptive mobility between sites
10. Latency between sites cannot be guaranteed to be <10ms end to end

Alternatives

1. Stretched Cluster between “Datacenter A” and “Datacenter B”
2. Two independent vCloud deployments with no automated DR
3. Have more/less hosts at the DR site in the same configuration

Implications

1. Two (2) ESXi hosts in the vCloud Cluster located in “Datacenter B” will remain unused as “Hot Standby” unless there is a declared site failure at “Datacenter A”
2. Requires two (2) vCenter servers , one (1) per Datacenter
3. There will be no non-disruptive mobility between sites (ie: vMotion)
4. SRM protection groups / plans need to be created/managed Note: This will be done as part of the Production cluster
5. In the event of a DR event, only half the compute resources will be available compared to production.
6. Depending on the latency between sites, storage performance may be reduced by the synchronous replication as the write will not be acknowledged to the VM at “Datacenter A” until committed to the storage at “Datacenter B”