IT Infrastructure Business Continuity & Disaster Recovery (BC/DR) – Corona Virus edition

Back in 2014, I wrote about Hardware support contracts & why 24×7 4 hour onsite should no longer be required. For those of you who haven’t read the article, I recommend doing so prior to reading this post.

In short, the post talked about the concept of the typical old-school requirement to have expensive 24/7, 2 or 4-hour maintenance contracts and how these become all but redundant when IT solutions are designed with appropriate levels of resiliency and have self-healing capabilities capable of meeting the business continuity requirements.

Some of the key points I made regarding hardware maintenance contracts included:

a) Vendors failing to meet SLA for onsite support.

b) Vendors failing to have the required parts available within the SLA.

c) Replacement HW being refurbished (common practice) and being faulty.

d) The more propitiatory the HW, the more likely replacement parts will not be available in a timely manner.

All of these are applicable to all vendors and can significantly impact the ability to get the IT infrastructure back online or back to a resilient state where subsequent failures may be tolerated without downtime or data loss.

I thought with the current Coronavirus pandemic, it’s important to revisit this topic and see what we can do to improve the resiliency of our critical IT infrastructure and ensure business continuity no matter what the situation.

Let’s start with “Vendors failing to meet SLA for onsite support.”

At the time of writing, companies the world over are asking employees to work from home and operate on skeleton staff. This will no doubt impact vendor abilities to provide their typical levels of support.

Governments are also encouraging social distance – that people isolate themselves and avoid unnecessary travel.

We would be foolish to assume this won’t impact vendor abilities to provide support, especially hardware support.

What about Vendors failing to have the required parts available within the SLA?

Currently I’m seeing significantly reduced flights operating, e.g.: From USA to Europe which will no doubt delay parts shipment to meet the target service level agreements.

Regarding vendors using potentially faulty refurbished (common practice) hardware, this risk in itself isn’t increased, but if this situation occurs, then the delays for shipment of alternative/new parts is likely going to be delayed.

Lastly, infrastructure leveraging propitatory HW makes it more likely that replacement parts will not be available in a timely manner.

What are some of the options Enterprise Architects can offer their customers/employers when it comes to delivering highly resilient infrastructure to meet/exceed business continuity requirements?

Let’s start with the assumption that replacement hardware isn’t available for one week, which is likely much more realistic than same-day replacement for the majority of customers considering the current pandemic.

Business Continuity Requirement #1: Infrastructure must be able to tolerate at least one component failure and have the ability to self heal back to a resilient state where a subsequent failure can be tolerated.

By component failure, I’m talking about things like:

a) HDD/SSDs

b) Physical server/node

c) Networking device such as a switch

d) Storage controller (SAN/NAS controllers, or in the case of HCI, a node)

HDDs/SSDs have been traditionally protected by using RAID and Hot Spares, although this is becoming less common due to RAID’s inherent limitations and high impact of failure.

For physical servers/nodes, products like VMware vSphere, Microsoft Hyper-V and Nutanix AHV all have “High Availability” functions which allow virtual machines to recover onto other physical servers in a cluster in the event of a physical server failure.

For networking, typically leaf/spine topologies provide a sufficient level of protection with a minimum of dual connections to all devices. Depending on the criticality of the environment, quad connections may be considered/required.

Lastly with Storage Controllers, traditional dual controller SAN/NAS have a serious constraint when it comes to resiliency in that they require the HW replacement to restore resiliency. This is one reason why Hyper-CXonverged Infrastructure (a.k.a HCI) has become so popular: Some HCI products have the ability to tolerate multiple storage controller failures and continue to function and self-heal thanks to their distributed/clustered architecture.

So with these things in mind, how do we meet our Business Continuity Requirement?

Disclaimer: I work for Nutanix, a company that provides Hyper-Converged Infrastructure (HCI), so I’ll be using this technology as my example of how resilient infrastructure can be designed. With that said the article and the key points I highlight are conceptual and can be applied to any environment regardless of vendor.

For example, Nutanix uses a Scale Out Shared Nothing Architecture to deliver highly resilient and self healing capabilities. In this example, Nutanix has a small cluster of just 5 nodes. The post shows the environment suffering a physical server failure, and then self healing both the CPU/RAM and Storage layers back to a fully resilient state and then tolerating a further physical server failure.

After the second physical server failure, it’s critical to note the Nutanix environment has self healed back to a fully resilient state and has the ability to tolerate another physical server failure.

In fact the environment has lost 40% of its infrastructure and Nutanix still maintains data integrity & resiliency. If a third physical server failed, the environment would continue to function maintaining data integrity, though it may not be able to tolerate a subsequent disk failure without data becoming unavailable.

So in this simple example of a small 5-node Nutanix environment, up to 60% of the physical servers can be lost and the business would continue to function.

With all these component failures, it’s important to note the Nutanix platform self healing was completed without any human intervention.

For those who want more technical detail, checkout my post which shows Nutanix Node (server) failure rebuild performance.

From a business perspective, a Nutanix environment can be designed so that the infrastructure can self heal from a node failure in minutes, not hours or days. The platform’s ability to self heal in a timely manner is critical to reduce the risk of a subsequent failure causing downtime or data loss.

Key Point: The ability for infrastructure to self heal back to a fully resilient state following one or more failures WITHOUT human intervention or hardware replacement should be a firm requirement for any new or upgraded infrastructure.

So the good news for Nutanix customers is during this pandemic or future events, assuming the infrastructure has been designed to tolerate one or more failures and self heal, the potential (if not likely) delay in hardware replacements is unlikely to impact business continuity.

For those of you who are concerned after reading this that your infrastructure may not provide the business continuity you require, I recommend you get in touch with the vendor/s who supplied the infrastructure and go through and document the failure scenarios and what impact this has on the environment and how the solution is recovered back to a fully resilient state.

Worst case, you’ll identify gaps which will need attention, but think of this as a good thing because this process may identify issues which you can proactively resolve.

Pro Tip: Where possible, choose a standard platform for all workloads.

As discussed in “Thing to consider when choosing infrastructure”, choosing a standard platform to support all workloads can have major advantages such as:

  1. Reduced silos
  2. Increased infrastructure utilisation (due to reduced fragmentation of resources)
  3. Reduced operational risk/complexity (due to fewer components)
  4. Reduced OPEX
  5. Reduced CAPEX

The article summaries by stating:

“if you can meet all the customer requirements with a standard platform while working within constraints such as budget, power, cooling, rack space and time to value, then I would suggest you’re doing yourself (or your customer) a dis-service by not considering using a standard platform for your workloads.”

What are some of the key factors to improve business continuity?

  1. Keep it simple (stupid!) and avoid silos of bespoke infrastructure where possible.
  2. Design BEFORE purchasing hardware.
  3. Document BUSINESS requirements AND technical requirements.
  4. Map the technical solution back to the business requirements i.e.: How does each design decision help achieve the business objective/s.
  5. Document risks and how the solution mitigates & responds to the risks.
  6. Perform operational verification i.e.: Validate the solution works as designed/assumed & perform this testing after initial implementation & maintenance/change windows.

Considerations for CIOs / IT Management:

  1. Cost of performance degradation such as reduced sales transactions/minute and/or employee productivity/moral
  2. Cost of downtime like Total outage of IT systems inc Lost revenue & impact to your brand
  3. Cost of increased resiliency compared to points 1 & 2
    1. I.e.: It’s often much cheaper to implement a more resilient solution than suffer even a single outage annually
  4. How employees can work from home and continue to be productive

Here’s a few tips to ask your architect/s when designing infrastructure:

  1. Document failure scenarios and the impact to the infrastructure.
  2. Document how the environment can be upgraded to provide higher levels of resiliency.
  3. Document the Recovery Time (RTO) and Recovery Point Objectives (RPO) and how the environment meets/exceeds these.
  4. Document under what circumstances the environment may/will NOT meet the desired RPO/RTOs.
  5. Design & Document a “Scalable and repeatable model” which allows the environment to be scaled without major re-design or infrastructure replacement to cater for unforeseen workload (e.g.: Such as a sudden increase in employees working from home).
  6. Avoid creating unnecessary silos of dissimilar infrastructure

Related Articles:

  1. Scale Out Shared Nothing Architecture Resiliency by Nutanix
  2. Hardware support contracts & why 24×7 4 hour onsite should no longer be required.
  3. Nutanix | Scalability, Resiliency & Performance | Index
  4. Nutanix vs VSAN / VxRAIL Comparison Series
  5. How to Architect a VSA , Nutanix or VSAN solution for >=N+1 availability.
  6. Enterprise Architecture and avoiding tunnel vision

Nutanix Resiliency – Part 9 – Self healing

Nutanix has a number of critically important & unique self healing capabilities which differentiate the platform from not only traditional SAN/NAS arrays but other HCI products.

Nutanix can fully automatically self heal not only from the loss of SSDs/HDDs/NVMe devices and node failure/s but also fully recover the management stack (PRISM) without user intervention.

First let’s go through the self healing of the data from device/node failure/s.

Let’s take a simple comparison between a traditional dual controller SAN and the average* size Nutanix cluster of eight nodes.

*Average is calculated by number of customers globally divide total nodes sold.

In the event of a single storage controller failure, the SAN/NAS is left with no resiliency and is at the mercy of the service level agreement (SLA) with the vendor to replace the component before resiliency (and in many cases performance) can be restored.

Compare that to Nutanix, and only one of the eight storage controllers (or 12.5%) are offline, leaving seven to continue serving the workloads and automatically restore resiliency, typically in just minutes as Part 1 demonstrated.

I’ve previously written a blog titled Hardware support contracts & why 24×7 4 hour onsite should no longer be required which covers this concept in more detail, but long story short, if restoring resiliency of a platform is dependant on the delivery of new parts, or worse, human intervention, the risk of downtime or dataloss is exponentially higher than a platform which can self heal back to a fully resilient state without HW replacement or human intervention.

Some people (or competitors) might argue, “What about a smaller (Nutanix) cluster?”.

I’m glad you asked, even a four node cluster can suffer a node failure and FULLY SELF HEAL into a resilient three node cluster without HW replacement or human intervention.

The only scenario where a Nutanix environment cannot fully self heal to a state where another node failure can be tolerated without downtime is a three node cluster. BUT, in a three node cluster, one node failure can be tolerated and data will be re-protected and the cluster will continue to function with just two nodes but a subsequent failure would result in downtime, but critically no data loss would occur.

Critically, Drive failures can still be tolerated in a degraded state where only two nodes are running.

Note: In the event of a node failure in a three node vSAN cluster, data is not re-protected and remains at risk until the node is replaced AND the rebuild is complete.

The only prerequisite for Nutanix to be able to perform the complete self heal of data (and even the management stack, PRISM) is that sufficient capacity exists within the cluster. How much capacity you ask, I recommend N-1 for RF2 configurations, or N+2 for RF3 configurations assuming two concurrent failures orone failure followed by a subsequent failure.

So worst case scenario for the minimum size cluster would be 33% for RF2 and 40% for a five node RF3 cluster. However, before the competitors break out the Fear, Uncertainty and Doubt (FUD), let’s look at how much capacity is required for self healing as the cluster sizes increase.

The following table shows the percentage of capacity required to fully self heal based on N+1 and N+2 for cluster sizes up to 32 nodes.

Note: These values assume the worst case scenario that all nodes are at 100% capacity so in the real world the overhead will be lower that the table indicates.

CapacityReservedForRebuild

As we can see, for an average size (eight node) cluster, the free space required is just 13% (rounded up from 12.5%).

If we take N+2 for an eight node cluster, the MAXIMUM free space required to tolerate two node failures and a full rebuild to a resilient state is still just 25%.

It is important to note that thanks to Nutanix Distributed Storage Fabric (ADSF), the free space does not need to account for large objects (e.g.: 256GB) as Nutanix uses 1MB extents which are evenly distributed throughout the cluster, so there is no wasted space due to fragmentation unlike less advanced platforms.

Note: The size of nodes in the cluster does not impact the capacity required for a rebuild.

A couple of advantages ADSF has over other platforms is that Nutanix does not have the concept of a “cache drive” or the construct of “disk groups”.

Using disk groups is a high risk to resiliency as a single “cache” drive failure can take an entire disk group (made up of several drives) offline forcing a much more intensive rebuild operation than is required. A single drive failure in ADSF is just that, a single drive failure and only the data on that drive needs to be rebuild, which is of course done in an efficient distributed manner (i.e.: A “Many to Many” operation as opposed to a “One to One” like other products).

The only time when a single drive failure causes an issue on Nutanix is with single SSD systems in which it’s the equivalent of a node failure, but to be clear this is not a limitation of ADSF, just that of the hardware specification chosen.

For production environments, I don’t recommend the use of single SSD systems as the Resiliency advantages outweigh the minimal additional cost of a dual SSD system.

Interesting point: vSAN is arguably always a single SSD system since a “Disk group” has just one “cache drive” making it a single point of failure.

I’m frequently asked what happens after a cluster self heals and another failure occurs. Back in 2013 when I started with Nutanix I presented a session at vForum Sydney where I covered this topic in depth. The session was standing room only and as a result of it’s popularity I wrote the following blog post which shows how a five node cluster can self heal from a failure into a fully resilient four node cluster and then tolerate another failure and self heal to a three node cluster.

This capability is nothing new and is far and away the most resilient architecture in the market even compared to newer platforms.

Scale Out Shared Nothing Architecture Resiliency by Nutanix

When you need to allow for failures of constructs such as “Disk Groups”, the amount of free space you need to reserve for failures in much higher as we can learn from a recent VMware vSAN article titled “vSan degraded device handling“.

Two key quotes to consider from the article are:

 we strongly recommend keeping 25-30% free “slack space” capacity in the cluster.

 

If the drive is a cache device, this forces the entire disk group offline

When you consider the flaws in the underlying vSAN architecture it becomes logical why VMware recommend 25-30% free space in addition to FTT2 (three copies of data).

Next let’s go through the self healing of the Management stack from node failures.

All components which are required to Configure, Manage, Monitor, Scale and Automate are fully distributed across all nodes within the cluster. There is no requirement for customers to deploy management components for core functionality (e.g.: Unlike vSAN/ESXi which requires VSAN).

There is also no need for users to make the management stack highly available, again unlike vSAN/ESXi.

As a result, there is no single point of failure with the Nutanix/Acropolis management layer.

Lets take a look at a typical four node cluster:

Below we see four Controller VMs (CVMs) which service one node each. In the cluster we have an Acropolis Master along with multiple Acropolis Slave instances.

Acropolis4nodecluster1

In the event the Acropolis Master becomes unavailable for any reason, an election will take place and one of the Acropolis Slaves will be promoted to Master.

This can be achieved because Acropolis data is stored in a fully distributed Cassandra database which is protected by the Acropolis Distributed Storage Fabric.

When an additional Nutanix node is added to the cluster, an Acropolis Slave is also added which allows the workload of managing the cluster to be distributed, therefore ensuring management never becomes a point of contention.Acropolis5NodeCluster

Things like performance monitoring, stats collection, Virtual Machine console proxy connections are just a few of the management tasks which are serviced by Master and Slave instances.

Another advantage of Nutanix is that the management layer never needs to be sized or scaled manually. There is no vApp/s , Database Server/s, Windows instances to deploy, install, configure, manage or license, therefore reducing cost and simplifying management of the environment.

Key point:

  1. The Nutanix Acropolis Management stack is automatically scaled as nodes are added to the cluster, therefore increasing consistency , resiliency, performance and eliminating potential for architectural (sizing) errors which may impact manageability.

The reason I’m highlighting a competitors product is because it’s important for customers to understand the underlying differences especially when it comes to critical factors such as resiliency for both the data and management layers.

Summary:

Nutanix ADSF provides excellent self healing capabilities without the requirement for hardware replacement for both the data and management planes and only requires the bare minimum capacity overheads to do so.

If a vendor led with any of the below statements (all true of vSAN), I bet the conversation would come to an abrupt halt.

  1. A single SSD is a single point of failure and causes multiple drives to concurrently go offline and we need to rebuild all that data
  2. We strongly recommend keeping 25-30% free “slack space” capacity in the cluster
  3. Rebuilds are a slow, One to One operation and in some cases do not start for 60 mins.
  4. In the event of a node failure in a three node vSAN cluster, data is not re-protected and remains at risk until the node is replaced AND the rebuild is complete.

When choosing a HCI product, consider it’s self healing capabilities for both the data and management layers as both are critical to the resiliency of your infrastructure. Don’t put yourself at risk of downtime by being dependant on hardware replacements being delivered in a timely manner. We’ve all experienced or at least heard of horror stories where vendor HW replacement SLAs have not been met due to parts not being available, so be smart, choose a platform which minimises risk by fully self healing.

Index:
Part 1 – Node failure rebuild performance
Part 2 – Converting from RF2 to RF3
Part 3 – Node failure rebuild performance with RF3
Part 4 – Converting RF3 to Erasure Coding (EC-X)
Part 5 – Read I/O during CVM maintenance or failures
Part 6 – Write I/O during CVM maintenance or failures
Part 7 – Read & Write I/O during Hypervisor upgrades
Part 8 – Node failure rebuild performance with RF3 & Erasure Coding (EC-X)
Part 9 – Self healing
Part 10: Nutanix Resiliency – Part 10 – Disk Scrubbing / Checksums

How to Architect a VSA , Nutanix or VSAN solution for >=N+1 availability.

How to architect a VSA, Nutanix or VSAN solution for the desired level of availability (i.e.: N+1 , N+2 etc) is a question I am asked regularly by customers and contacts throughout the industry.

This needs to be addressed in two parts.

1. Compute
2. Storage

Firstly, Compute level resiliency, As a cluster grows, the chances of a failure increases so the percentage of resources reserved for HA should increase with the size of the cluster.

My rule of thumb (which is quite conservative) is as follows:

1. N+1 for clusters of up to 8 hosts
2. N+2 for clusters of >8 hosts but <=16
3. N+3 for clusters of >16 hosts but <=24
4. N+4 for clusters of >24 hosts but <=32

The above is discussed in more detail in : Example Architectural Decision – High Availability Admission Control Setting and Policy

The below table highlights in Green my recommended HA percentage configuration based on the cluster size, up to the current vSphere limit of 32 nodes.

HApercentages

Some of you may be thinking, if my Nutanix or VSAN cluster is only configured for RF2 or FT1 for VSAN, I can only tolerate one node failure, so why am I reserving more than N+1.

In the case of Nutanix, after a node failure, the cluster can restore itself to a fully resilient state and tolerate subsequent failures. In fact, with “Block Awareness” a full 4 node block can be lost (so an N-4 situation) which if this is a requirement, needs to be considered for HA admission control reservations to ensure compute level resources are available to restart VMs.

Next lets talk about the issue perceived to be more complicated, Storage redundancy.

Storage redundancy for VSA, Nutanix or VSAN is actually not as complicated as most people think.

The following is my rule of thumb for sizing.

For N+1 , Ensure you have enough capacity remaining in the cluster to tolerate the largest node failing.

For N+2, Ensure you have enough capacity remaining in the cluster to tolerate the largest TWO nodes failing.

The examples below discuss Nutanix nodes and their capacity, but the same is applicable to any VSA or VSAN solution where multiple copies of data is kept for data protection, as opposed to RAID.

Example 1 , If you have 4 x Nutanix NX3060 nodes configured with RF2 (FT1 in VSAN terms) with 2TB usable per node (as shown below), in the event of a node failure, 2TB is no longer available. So the maximum storage utilization of the cluster should be <75% (6TB) to ensure in the event of any node failure, the cluster can be restored to a fully resilient state.

4node3060

Example 2 , If you have 2 x Nutanix NX3060 nodes configured with RF2 (FT1 in VSAN terms) with 2TB usable per node and 2 x Nutanix NX6060 nodes with 8TB usable per node (as shown below), in the event of a NX6060 node failure, 8TB is no longer available. So the maximum storage utilization of the cluster should be 12TB to ensure in the event of any node failure (including the 8TB nodes), the cluster can be restored to a fully resilient state.

4nodemixed

For environments using Nutanix RF3 (3 copies of data) or VSAN (FT2) the same rule of thumb applies but the usable capacity per node would be lower due to the increased capacity required for data protection.

Specifically for Nutanix environments, the PRISM UI shows if a cluster has sufficient capacity available to tolerate a node failure, and if not the following is displayed on the HOME screen and alerts can be sent if desired.

CapacityCritical

In this case, the cluster has suffered a node failure, and because it was sized suitably, it shows “Rebuild Capacity Available” as “Yes” and advises an “Auto Rebuild in progress” meaning the cluster is performing a fully automated self heal. Importantly no admin intervention is required!

If the cluster status is normal, the following will be shown in PRISM.

CapacityOK

In summary: The smaller the cluster the higher the amount of capacity needs to remain unused to enable resiliency to be restored in the event of a node failure, the same as the percentage of resources reserved for HA in a traditional compute only cluster.

The larger the cluster from both a storage and compute perspective, the lower the unused capacity is required for HA, so as has been a virtualization recommended practice for years….. Scale-out!